Positive opening
With NC contact
Supply voltage type
AC/DC
Supply frequency
50/60 Hz
Power consumption in VA
10 VA inrush
10 VA sealed
Signalling circuit type
AC/DC
Signalling circuit consumption
7 mA
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Maximum actuation speed
0.5 m/s
[Ie] rated operational current
0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1
0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
6 A
[Ui] rated insulation voltage
50 V conforming to IEC 60947-1 for signalling circuit
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
Protection type
Overvoltage protection for signalling circuit
Short-circuit protection
10 A cartridge fuse type gG (gl)
Actuator forcible withdrawal rtc
2000 N
Minimum actuator force for extraction
20 N
Maximum operating rate
10 cyc/mn for maximum durability
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear