XCSRC10M12

Preventa RFID safety switch, Telemecanique Safety switches XCS, contactless Single model, Unique pairing

END OF COMMERC ANNOUNCED Date d'arrêt de fabrication : June 01st 2023 Fin de prestation de service : June 01st 2023

XCSRC10M12 is replaced by the following product:

img

Quantity :  1

Déplier tout

Fiche technique

Commercial Reference
XCSRC10M12
PIM CR type
Standard Commercial Reference
Product sub-type
Standard CR
Product typology
Referenced Sold Product
Short description
RFID SINGLE SAFETY SENSOR UNIQUE PAIRING
Medium description
Preventa RFID safety switch, Telemecanique Safety switches XCS, contactless Single model, Unique pairing
Website publication
1
Product manager
Yuan ZHANG
Base unit of measure
PCE
ERP-Print medium description
RFID SINGLE SAFETY SENSOR UNIQUE PAIRING
ETIM classification
ETIM 9 - EC002544 - Magnetic proximity switch
***TABLE***
Commercial status
14 - End of comm. announced
Warranty
-
Country of origin
FR (France)
Density of package
0 GRAM_PER_CUBIC_CENTIMETER
[BMEcat] Reach info
True
[BMEcat] RoHS indicator
True
Equipment category according to Annex I of EU RoHS 2011/65/EU
9i
1907/2006 - Reach regulation - Annex XVII status
Free of any substance listed in Annex XVII above threshold
California proposition
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
EU RoHS 2011/65/EU compliance status
Compliant with exemption(s)
1907/2006 - Reach regulation - EC number(s)
231-100-4;209-136-7;208-764-9;208-762-8
1907/2006 - Reach regulation - CAS number(s)
7439-92-1;556-67-2;541-02-6;540-97-6
1907/2006 - Reach regulation - SCIP ID
Ae2c9248-7cf2-40c5-9c81-79ca513bed7d
1907/2006 - Reach regulation - SVHC content(s)
Lead;Octamethylcyclotetrasiloxane (D4);Decamethylcyclopentasiloxane (D5);Dodecamethylcyclohexasiloxane (D6)
1907/2006 - Reach regulation - Specific safe conditions of use
None;None;None;None
1907/2006 - Reach regulation - Candidate list version
June 2025
2011/65/EU - RoHS - Exemptions according to Annex III
6(c);7(a);7(c)-I
GTIN
3389119634847
EAN13
3389119634847
Dangerous goods code
Not Applicable
Package 1 GTIN
3389119634847
Package 1 width
14.9 CENTIMETER
HS6 customs code (global)
853650
Package 1 height
3.7 CENTIMETER
Package 1 length
18 CENTIMETER
Package 1 weight
0.106 KILOGRAM
Volume of package 1
992.34 CUBIC_CENTIMETER
Indivisible sale quantity
1
Number of units in package 1
1
Unit type of package 1
PCE
Package 1 bare product quantity
1

Déplier tout

Schéma technique​

Dimensions

epds

Connections

M12 Connector, 5-pin

epds
  • (1) + 24 VDC
  • (2) OSSD2
  • (3) 0 VDC
  • (4) OSSD1
  • (5) NC (Not connected)

Connections

Wiring Diagram: Connection to a Safety Relay

epds
  • (1) Transponder
  • (2) Reader
  • (3) Logic
  • (4) Start
  • (5) ESC: External start conditions
  • (6) H1: indicator light deactivated
  • (7) Fuse. Operating status of internal electronic fuse
  • (8) To PLC
  • (9) Power circuit

Connections

Wiring Diagram: Connection to a Safety Controller

epds
  • (1) Power supply
  • (2) 1 A max.
  • (3) Safety controller
  • (4) Feedback
  • (5) Restart
  • (6) Reader
  • (7) Transponder
  • (8) Power circuit

Mounting and Clearance

Mounting and Clearance

Face to Face Mounting (Preferred Configuration)

epds
  • e min. > 2 mm. (e: recommended minimum mounting distance between transponder and reader)
  • d : Detection limit

Mounting and Clearance

Side by Side Mounting

epds
  • e: Recommended minimum mounting distance between transponder and reader.

Mounting and Clearance

Minimum Mounting Clearances between Safety Switches

epds

Detection Curves

Face to Face Mounting (Preferred Configuration)

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.

Detection Curves

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.

Detection Curves

Side by Side Mounting

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.

Detection Curves

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.

Déplier tout

Documents et téléchargements

Document name
Date
Taille

Déplier tout

Produits et accessoires associés

Back to top

arrow