XUM2APCNL2R

Photoelectric sensors XU, XUM, receiver, 15 m, 12...24 VDC, cable 2 m

End of commercialisation Date d'arrêt de fabrication : April 27th 2022 Fin de prestation de service : April 27th 2022

XUM2APCNL2R is replaced by the following product:

img
XUM2APXBL2

Photoelectric sensors XU, miniature, thru beam, Smax=30 m, system, PNP, cable 2 m

Quantity :  1

Déplier tout

Fiche technique

Range of product
Telemecanique Photoelectric sensors XU
Series name
General purpose single mode
Electronic sensor type
Photo-electric sensor receiver
Sensor name
XUM
Sensor design
Miniature
Detection system
Thru beam
Sensing range
> 5...15 m
Material
Plastic
Type of output signal
Discrete
Supply circuit type
DC
Wiring technique
3-wire
[Sn] nominal sensing distance
15-15 m thru beam need a transmitter XUM2AKCNL2T
Discrete output type
PNP
Discrete output function
1 NO or 1 NC programmable
Electrical connection
Cable
Product specific application
Not applicable
Emission
Red thru beam
Enclosure material
PBT
Lens material
PMMA
Output type
Solid state
Status LED
1 LED (red) for indicator light, 1 LED (green) for instability and supply on
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
Switching capacity in mA
<= 100 mA (overload and short-circuit protection)
Switching frequency
1000 Hz
Maximum voltage drop
<3 V (closed state)
Current consumption
13 mA no-load
Delay first up
100 MILLISECOND
Delay response
0.5 MILLISECOND
Delay recovery
0.5 MILLISECOND
Setting-up
Sensitivity adjustment
Supply voltage limits
10-30 V DC
Vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
Shock resistance
30 gn (duration = 11 ms) conforming to IEC 60068-2-27
IP degree of protection
IP67 conforming to IEC 60529, IP65 conforming to IEC 60529
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
1.5 CENTIMETER
Package 1 width
15 CENTIMETER
Package 1 length
15 CENTIMETER
Package 1 weight
63 GRAM
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Déplier tout

Schéma technique​

Receiver's Dimensions

epds
  • R : Reception
  • (1) Output state LED on front face

Mounting and Clearance

epds
  • (1) Configuration switch
  • (2) Output state LED
  • (3) Stability and power on LED

Connections and Schemes

PNP

epds
  • BN : Brown
  • BU : Blue
  • BK : Black

Detection Curves

epds
  • (Y) Parallel movement (cm)
  • (X) Distance (m)

Déplier tout

Produits et accessoires associés

img
XUZA50

Fixing bracket, Photoelectric sensors XU, accessory for sensor, XUM, metal

Back to top

arrow