XCSTA792

Safety switch, Telemecanique Safety switches XCS, plastic XCSTA, 2 NC + 1 NO, slow break, 2 entries tappedM16

arrow

Commercialised

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Safety switch
Component name
XCSTA
Design
Compact
Material
Plastic
Head type
Key operated turret head
Contacts type and composition
2 NC + 1 NO
Contact operation
Slow-break, break before make
Cable entry
2 entries tapped for M16 x 1.5
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Locking options description
Without locking of actuator
Insulation
Double insulated
Positive opening
With NC contact
Operating rate
10 cyc/mn for maximum durability
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body material
PA (polyamide)
Head material
PA (polyamide)
Standards
CSA C22.2 No 14
EN 1088/ISO 14119
IEC 60204-1
IEC 60947-5-1
ISO 12100
UL 508
Product certifications
CSA
UL
Protective treatment
TC
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class II conforming to IEC 61140
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Unit type of package 1
PCE
Number of units in package 1
1
Unit type of package 2
S01
Number of units in package 2
15
Package 2 height
15 CENTIMETER
Package 2 width
15 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
2.79 KILOGRAM
Indivisible sale quantity
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expand all

Documents & Downloads

Document name
Date
Size
Document name
Date
Size

Expand all

Related products & accessories

img
XCSZ11

Telemecanique Safety switches XCS, straight actuator, for plastic switch

img
XCSZ12

Telemecanique Safety switches XCS, actuator with wide fixing, length 40 mm, for plastic switch

img
XCSZ13

Telemecanique Safety switches XCS, pivoting actuator, for plastic switch

Back to top

arrow