XXA18B1PM12

Ultrasonic sensors XX, ultrasonic sensor cylindrical 90 deg M18, Sn=1 m, PNP, SYNC, connector M12

arrow

COMMERCIALISED

Expandir todo

Ficha de datos

Range of product
Telemecanique Ultrasonic sensors XX
Sensor type
Ultrasonic sensor
Series name
General purpose
Sensor name
XXA
Sensor design
Cylindrical M18
Detection system
Diffuse (with 90° head)
Material
Metal
Type of output signal
Discrete
Discrete output function
1 NO or 1 NC programmable
Wiring technique
5-wire
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
Discrete output type
PNP
Electrical connection
Male connector M12 5 pins
Enclosure material
Nickel plated brass
Front material
Epoxy
resin
rubber
Function available
Software configurable
with synchronisation mode
Voltage drop
2 VOLT
Minimum size of detected object
Cylinder diameter 1 mm at 600 mm
Delay first up
120 MILLISECOND
Current consumption
30 mA
Status LED
Output state: 1 LED (yellow), echo state: 1 LED (green)
Setting-up
Configurator software
teach mode
Switching frequency
11 Hz
Delay response
45 MILLISECOND
Delay recovery
45 MILLISECOND
IP degree of protection
IP65 conforming to IEC 60529, IP67
Marking
CE
Standards
CSA C22.2 No 14
IEC 60947-5-2
UL 508
Product certifications
cULus
E2
Ecolab
RCM
Vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10-55 Hz)
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
8.89 CENTIMETER
Package 1 width
8.64 CENTIMETER
Package 1 length
4.06 CENTIMETER
Package 1 weight
0.08 KILOGRAM
Unit type of package 3
CAR
Number of units in package 3
1
Package 3 height
4.1 CENTIMETER
Package 3 width
6.4 CENTIMETER
Package 3 length
9.4 CENTIMETER
Unit type of package 2
S01
Package 3 weight
0.05 KILOGRAM
Number of units in package 2
15
Package 2 height
15 CENTIMETER
Package 2 width
15 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
0.975 KILOGRAM
Indivisible sale quantity
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expandir todo

Dibujos tecnicos

Dimensions

epds

Connections

Connector Wiring

epds
  • (1) : Synchronization
  • (2) : External setting pushbutton or XXZPB100 remote teach pushbutton.

Connections

Wiring Scheme

epds
  • (1) : Synchronization
  • (2) : External setting pushbutton or XXZPB100 remote teach pushbutton.
  • (1) : Synchronization

Connections

Wiring for the Synchronization Function (Side by Side Application)

epds
  • (1) : Synchronization
  • (2) : External setting pushbutton or XXZPB100 remote teach pushbutton.
  • (1) : Synchronization
  • BN : Brown
  • WH : White
  • BU : Blue
  • BK : Black
  • GY : Grey

Performance Curves

Detection Curve with 100 x 100 mm / 3.94 x 3.94 in. Square Target

epds
  • (x) Target distance
  • (y) Detection limit
  • (1) : Blind zone: 105 mm
  • (2) : Sn max.
  • (3) : 100 x 100 mm / 3.94 x 3.94 in. stainless steel plate

Performance Curves

Detection Curve with Round Bar

epds
  • (x) Target distance
  • (y) Detection limit
  • (1) : Blind zone: 105 mm
  • (2) : Sn max.
  • (3) : 100 x 100 mm / 3.94 x 3.94 in. stainless steel plate
  • (x) Target distance
  • (y) Detection limit
  • (1) : Blind zone: 105 mm
  • (2) : Sn max.
  • (3) : Ø 10 mm / 0.394 in. stainless steel cylinder
  • (4) : Ø 25 mm / 0.984 in. stainless steel cylinder

Operating Diagrams Settings with Teach Procedure

Window Mode

epds
  • (1) : Near limit
  • (2) : Far limit
  • (3) : Sensing window

Operating Diagrams Settings with Teach Procedure

Reflex Mode

epds
  • (1) : Near limit
  • (2) : Far limit
  • (3) : Sensing window
  • (1) : In reflex mode, the position of the reflector must be at least 315 mm away from the sensor.
  • (2) : Reflector
  • (3) : Near limit
  • (4) Far limit

Operating Diagrams Settings with Teach Procedure

Proximity Mode

epds
  • (1) : Near limit
  • (2) : Far limit
  • (3) : Sensing window
  • (1) : In reflex mode, the position of the reflector must be at least 315 mm away from the sensor.
  • (2) : Reflector
  • (3) : Near limit
  • (4) Far limit
  • (1) : Switch point

Operating Diagrams Settings with Teach Procedure

Pump/Hysteresis Mode

epds
  • (1) : Near limit
  • (2) : Far limit
  • (3) : Sensing window
  • (1) : In reflex mode, the position of the reflector must be at least 315 mm away from the sensor.
  • (2) : Reflector
  • (3) : Near limit
  • (4) Far limit
  • (1) : Switch point
  • (1) : Adjustable detection zone
  • (2) : Output activated
  • (3) : Output deactivated
  • (4) NO output

Operating Diagrams Settings with Teach Procedure

epds
  • (1) : Near limit
  • (2) : Far limit
  • (3) : Sensing window
  • (1) : In reflex mode, the position of the reflector must be at least 315 mm away from the sensor.
  • (2) : Reflector
  • (3) : Near limit
  • (4) Far limit
  • (1) : Switch point
  • (1) : Adjustable detection zone
  • (2) : Output activated
  • (3) : Output deactivated
  • (4) NO output
  • (1) : Adjustable detection zone
  • (2) : Output activated
  • (3) : Output deactivated
  • (4) NO output

Expandir todo

Documentos y Descargas

Nombre del documento
Fecha
Tamaño
Nombre del documento
Fecha
Tamaño

Expandir todo

Productos y accesorios relacionados

Back to top

arrow