XMLK010B2D21TQ

Electronic pressure sensors, Pressure sensors XM, sensor XMLK, 0...10 bar, G 1/4 A, 4...20 mA, M12, set of 25

End of commercialisation Fecha de fin de comercialización : April 20th 2022 Fecha de fin del servicio : April 20th 2022

Expandir todo

Ficha de datos

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLK
Electrical circuit type
Control circuit
Local display
Without
Controlled fluid
Air (0-80 °C), fresh water (0-80 °C)
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
Electrical connection
1 male connector M12 4 pins
[Us] rated supply voltage
24 V DC SELV (voltage limits: 8-33 V)
Current consumption
20 mA
Type of output signal
Analogue
Analogue output function
4...20 mA, 2-wire
Quantity per set
Set of 25
Type of packing
Group
Materials in contact with fluid
Ceramic
nitrile (NBR)
stainless steel type AISI 303
Operating position
Any position
Protection type
Load short-circuit
reverse polarity
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 6 kV contact, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, immunity to magnetic fields conforming to IEC 61000-4-8 30 A/m 50 Hz
Response time on output
< 5 ms
Measurement accuracy
+/- 1 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,04 % of measuring range/°K
Drift of the zero point
+/- 0,03 % of measuring range/°K
Repeat accuracy
+/- 1 % de la plage de mesure
Standards
CE
IEC 61326-2-3
Product certifications
CSA C22-2 No 14
RCM
UL 508
Protective treatment
TC
Vibration resistance
20 gn (f = 9-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
25 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
NEMA degree of protection
NEMA 4
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
11.1 CENTIMETER
Package 1 width
20 CENTIMETER
Package 1 length
20 CENTIMETER
Package 1 weight
110 GRAM
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expandir todo

Dibujos tecnicos

Dimensions

epds

Wiring Diagram

2-Wire Technique (4-20 mA)

epds
  • (a) I out

Output Curves

epds

Back to top