Product destination
For closed tank
Device mounting
Screw-in bushing
Cable entry number
3 knock-outs for 1/2" conduit conforming to UL 508
Contacts type and composition
2 NO, snap action, DPST-DB, Form XX
Controlled fluid
Fresh water at specific gravity of 0.85 in or higher -18…121 °C
Sea water at specific gravity of 0.85 in or higher -18…121 °C
Hydraulic oil at specific gravity of 0.85 in or higher -18…121 °C
Corrosive fluid at specific gravity of 0.85 in or higher -18…121 °C
Motor power kW
1.5 kW (2 hp) at 115 V AC, 1 phase
2.2 kW (3 hp) at 115 V AC, 3 phases
2.2 kW (3 hp) at 230 V AC, 1 phase
3.7 kW (5 hp) at 230 V AC, 3 phases
0.75 kW (1 hp) at 460 V AC, 3 phases
0.75 kW (1 hp) at 475 V AC, 3 phases
0.18 kW (0.25 hp) at 32 V DC
0.37 kW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection
Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation
Contacts open on liquid rise
Float movement
2...5 in adjustable
Short-circuit protection
20 A cartridge fuse, type gG
Local signalling
With external pointer
Materials in contact with fluid
Viton
Stainlesss steel 304
Stainless steel 316
Cast iron
Yellow brass
Enclosure material
Polypropylene or equivalent
Operating position
Vertical position only
Electrical durability
100 cycles, operating rate <60 cyc/mn
Mechanical durability
300 cycles
Terminal block type
4 terminals
Maximum operating rate
60 cyc/mn
[Ui] rated insulation voltage
575 V conforming to UL 508
Terminals description ISO n°1
Line-load-load-line
Factory modification
Without
Kit composition
Float switch
Float
Rod