9037HR33

Float switch, Pumptrol, closed tank, NEMA 7/9, screw in bushing, 2 NC DPST DB contacts

arrow

Commercialized

Expand all

Datasheet

Range of produc
Pumptrol
Product or component type
Float switch
Device application
Closed tank
Device short name
9037H
Product specific application
Liquid level control
Electrical circuit type
Power circuit
Quantity per set
Set of 1
Type of packing
Individual
Product destination
For closed tank
Device mounting
Screw-in bushing
Cable entry number
2 conduit entries for 3/4"-14 NPT conforming to UL 508
Contacts type and composition
2 NC, snap action, DPST-DB, Form YY
Controlled fluid
Fresh water at specific gravity of 0.85 in or higher -18…104 °C
Sea water at specific gravity of 0.85 in or higher -18…104 °C
Hydraulic oil at specific gravity of 0.85 in or higher -18…104 °C
Corrosive fluid at specific gravity of 0.85 in or higher -18…104 °C
Motor power kW
1.5 kW (2 hp) at 115 V AC, 1 phase
2.2 kW (3 hp) at 115 V AC, 3 phases
2.2 kW (3 hp) at 230 V AC, 1 phase
3.7 kW (5 hp) at 230 V AC, 3 phases
0.75 kW (1 hp) at 460 V AC, 3 phases
0.75 kW (1 hp) at 475 V AC, 3 phases
0.18 kW (0.25 hp) at 32 V DC
0.37 kW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection
Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation
Contacts close on liquid rise
Float movement
2...5 in adjustable
Float position
Right
Float rod angle
45°
Short-circuit protection
20 A cartridge fuse, type gG
Local signalling
With external pointer
Materials in contact with fluid
Nitrile (Buna-N) or equivalent rubber
Yellow brass
Stainlesss steel 304
Cast iron
Stainless steel 316
Enclosure material
Cast aluminium
Operating position
Vertical position only
Electrical durability
100 cycles, operating rate <60 cyc/mn
Mechanical durability
300 cycles
Terminal block type
4 terminals
Maximum operating rate
60 cyc/mn
[Ui] rated insulation voltage
575 V conforming to UL 508
Terminals description ISO n°1
Line-load-load-line
Factory modification
Without
Kit composition
Float
Float switch
Rod
Standards
UL 508
CE
Ambient air temperature for operation
-30…93 °C
Ambient air temperature for storage
-30…93 °C
NEMA degree of protection
NEMA 7/9 conforming to UL 698
Product certifications
UL listed HazLoc
CSA
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
19.05 cm
Package 1 Width
24.13 cm
Package 1 Length
34.29 cm
Package 1 Weight
4.367 kg
REACh Regulation
EU RoHS Directive
Not applicable, out of EU RoHS legal scope
Environmental Disclosure
Circularity Profile
California proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months

Expand all

Documents & Downloads

Document name
Date
Size

Back to top

arrow