Product destination
For open tank
Cable entry number
2 conduit entries for 3/4"-14 NPT conforming to UL 508
Contacts type and composition
4 NC, snap action, DPST-DB, Form YY
Controlled fluid
Fresh water at specific gravity of 0.85 in or higher
Sea water at specific gravity of 0.85 in or higher
Hydraulic oil at specific gravity of 0.85 in or higher
Corrosive fluid at specific gravity of 0.85 in or higher
Motor power kW
1.5 kW (2 hp) at 115 V AC, 1 phase
2.2 kW (3 hp) at 115 V AC, 3 phases
2.2 kW (3 hp) at 230 V AC, 1 phase
3.7 kW (5 hp) at 230 V AC, 3 phases
0.75 kW (1 hp) at 460 V AC, 3 phases
0.75 kW (1 hp) at 475 V AC, 3 phases
0.18 kW (0.25 hp) at 32 V DC
0.37 kW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection
Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation
Contacts close on liquid rise
Float movement
Variable adjustable
Short-circuit protection
20 A cartridge fuse, type gG
Enclosure material
Cast aluminium
Operating position
Vertical position only
Electrical durability
100 cycles, operating rate <60 cyc/mn
Mechanical durability
300 cycles
Terminal block type
8 terminals
Maximum operating rate
60 cyc/mn
[Ui] rated insulation voltage
575 V conforming to UL 508
Terminals description ISO n°1
Line-load-load-line
Factory modification
Addition of a third, high-water alarm circuit (SPST-NO-DB)
Kit composition
Rod and float are to be choosen in accessories
Float switch