Product destination
For closed tank
Device mounting
Screw-in bushing
Cable entry number
2 conduit entries for 3/4"-14 NPT conforming to UL 508
Contacts type and composition
4 NC, snap action, DPST-DB, Form YY
Controlled fluid
Fresh water at specific gravity of 0.85 in or higher -18…121 °C
Sea water at specific gravity of 0.85 in or higher -18…121 °C
Hydraulic oil at specific gravity of 0.85 in or higher -18…121 °C
Corrosive fluid at specific gravity of 0.85 in or higher -18…121 °C
Motor power kW
1.5 kW (2 hp) at 115 V AC, 1 phase
2.2 kW (3 hp) at 115 V AC, 3 phases
2.2 kW (3 hp) at 230 V AC, 1 phase
3.7 kW (5 hp) at 230 V AC, 3 phases
0.75 kW (1 hp) at 460 V AC, 3 phases
0.75 kW (1 hp) at 475 V AC, 3 phases
0.18 kW (0.25 hp) at 32 V DC
0.37 kW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection
Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation
Contacts close on liquid rise
Float movement
4...7.75 in adjustable
Float rod angle
90° (offset)
Short-circuit protection
20 A cartridge fuse, type gG
Local signalling
With external pointer
Materials in contact with fluid
Yellow brass
Stainless steel 316
Viton
Stainlesss steel 304
Cast iron
Enclosure material
Cast aluminium
Operating position
Vertical position only
Electrical durability
100 cycles, operating rate <60 cyc/mn
Mechanical durability
300 cycles
Terminal block type
8 terminals
Maximum operating rate
60 cyc/mn
[Ui] rated insulation voltage
575 V conforming to UL 508
Terminals description ISO n°1
Line-load-load-line
Factory modification
Without
Kit composition
Float
Float switch
Rod