Mechanical durability
30000000 cycles
Minimum torque for tripping
0.25 N.m
Minimum actuation speed
6 m/mn
Maximum actuation speed
1.5 m/s
Cable entry
1 entry tapped for Pg 13.5 cable gland, cable outer diameter: 9-12 mm
Electrical durability
5000000 cycles, DC-13, inductive load type, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, inductive load type, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Contacts insulation form
Zb
Contacts type and composition
1 NC + 1 NO
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Contact operation
Slow-break, break before make
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664, 6 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
Overvoltage category
Class I conforming to IEC 61140, class I conforming to NF C 20-030
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1 appendix A, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Short-circuit protection
10 A cartridge fuse, type gG