Mechanical durability
10000000 cycles
Minimum torque for tripping
0.1 N.m
Maximum actuation speed
1.5 m/s
Cable entry
1 entry tapped for M16 x 1.5 cable gland, cable outer diameter: 4-8 mm
Contact code designation
A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to IEC 60947-5-1 appendix A, Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
Electrical durability
5000000 cycles, DC-13, 120 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Positive opening minimum torque
0.25 N.m
Contacts insulation form
Zb
Contacts type and composition
2 NC
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Contact operation
Slow-break, simultaneous
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60664, 6 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
Electrical shock protection class
Class II conforming to IEC 61140, class II conforming to NF C 20-030
Short-circuit protection
10 A cartridge fuse, type gG