XCSC503

Safety switch XCSC, metal, 1NC+2NO, slow break, 1 entry tapped 1/2" NPT

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Safety switch
Component name
XCSC
Design
Industrial
Sensor design
INDUSTRIAL
ETIM classification
ETIM 9 - EC002593 - Position switch with guard locking
Head type
Key operated turret head
Material
Metal
Body material
Zamak
Head material
Zamak
Number of poles
3
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Locking options description
With locking of actuator, unlocking by key operated lock
Product certifications
CSA
UL
Standards
CSA C22.2 No 14
EN 1088/ISO 14119
IEC 60204-1
IEC 60947-5-1
ISO 12100
UL 508
Indivisible sale quantity
1
Actuator force for extraction
20 N
Actuator forcible withdrawal rtc
1500 N
Mechanical durability
600000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
1 entry tapped for 1/2" NPT
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Positive opening
With NC contact
Contacts type and composition
1 NC + 2 NO
Contact operation
Slow-break, break before make
Operating rate
10 cyc/mn for maximum durability
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ie] rated operational current
6 A at 120 V, AC-15, A300 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
10 A
Electrical shock protection class
Class I conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Local signalling
Without
Width
52 mm
Depth
44 mm
Product weight
0.48 kg
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
FR (France)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916049075
Package 1 height
5 cm
Package 1 width
6.7 cm
Package 1 length
12.2 cm
Package 1 weight
0.499 kg
New Package 2 GTIN 14
13666916049072
Package 2 height
5 cm
Package 2 width
6.7 cm
Package 2 length
12.2 cm
Package 2 weight
499 kg
New Package 3 GTIN 14
23666916049079

Expand all

Documents & Downloads

Document name
Date
Size

Expand all

Related products & accessories

Back to top

arrow