Actuator force for extraction
20 N
Actuator forcible withdrawal rtc
2000 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
2 entries tapped for 1/2" NPT
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Positive opening
With NC contact
Contacts type and composition
3 NC
Solenoid contacts type and composition
1 NC + 1 NO (slow-break, simultaneous)
Contact operation
Slow-break, simultaneous
Operating rate
10 cyc/mn for maximum durability
[Us] rated supply voltage
110/120 V - 20...10 %
Supply voltage type
AC/DC
Supply frequency
50/60 Hz
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
250 V conforming to IEC 60947-1 for signalling circuit
Signalling circuit voltage
110/240 V (voltage limits: 95...264 V)
[Ie] rated operational current
0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1, 3 A at 120 V, AC-15, B300 conforming to IEC 60947-5-1, 1.5 A at 240 V, AC-15, B300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
6 A
Power consumption in VA
10 VA inrush, 10 VA sealed
Electrical shock protection class
Class I conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Local signalling
2 LEDs (green or orange) for guard open/guard closed and locked
Signalling circuit consumption
7 mA
Signalling circuit type
AC
Protection type
Overvoltage protection for signalling circuit