XMLB010A2S12EX

Pressure switch, XMLB, pressure range 10 bar, adjustable scale, 1CO, 2 thresholds

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Pressure sensor type
Electromechanical pressure sensor
Product specific application
ATEX D
Pressure sensor name
XMLB
Electrical circuit type
Control circuit
Pressure switch type of operation
Regulation between 2 thresholds
Scale type
Adjustable differential
Local display
With
Fluid connection type
G 1/4 (female) conforming to ISO 228
Pressure actuator
Diaphragm
Controlled fluid
Air (0-70 °C), hydraulic oil (0-70 °C), water (0-70 °C)
Materials in contact with fluid
Nitrile
zinc alloy
Enclosure material
Zinc alloy
Terminal block type
4 terminals
Auxiliary contacts operation
Snap action
Contacts material
Silver contacts
Setting
External
Terminals description ISO n°1
(13-14-11-12)OF
Standards
EN/IEC 60079-0
EN/IEC 60079-31
Directives
2014/34/EU - ATEX directive
Product certifications
IEC-Ex INE 17.0019
INERIS 04ATEX0058
Marking
II2 D-Ex tb IIIC T85°C Db IP66
Protective treatment
TC
Operating position
Any position
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
9 CENTIMETER
Package 1 width
9.5 CENTIMETER
Package 1 length
16 CENTIMETER
Package 1 weight
0.785 KILOGRAM
Unit type of package 2
S03
Number of units in package 2
12
Package 2 height
30 CENTIMETER
Package 2 width
30 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
9.922 KILOGRAM
Indivisible sale quantity
1

Expand all

Technical Drawings

Dimensions

epds
  • (1) 1 fluid entry, tapped G1/4 (BSP female)
  • (2) 1 electrical connections entry, tapped M20 x 1.5
  • Ø : 2 elongated holes Ø 5.2 x 6.7

Wiring Diagram

Terminal Model

epds

Operating Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential
epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • PH : High point
  • PB : Below point

Expand all

Related products & accessories

Back to top

arrow