XMLC002B2S11

Pressure switch, XMLC, pressure range 2.5 bar, adjustable scale, 2CO, 2 thresholds

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Pressure sensor type
Electromechanical pressure sensor
Product or component type
Electromechanical pressure sensor
Device short name
XMLC
Product specific application
Not applicable
ETIM classification
ETIM 9 - EC000243 - Pressure switch
Enclosure material
Zinc alloy
Materials in contact with fluid
FPM, FKM
steel
Pressure switch type of operation
Regulation between 2 thresholds
Operating position
Any position
Pressure sensor size
2.5 Bar
Maximum permissible accidental pressure
9 Bar
Maximum permissible pressure - per cycle
5 Bar
Destruction pressure
18 Bar
Pressure actuator
Diaphragm
Possible differential maximum at high setting
2 Bar
Controlled fluid
Air (0-160 °C), fresh water (0-160 °C), hydraulic oil (0-160 °C)
Fluid connection type
G 1/4 (female) conforming to ISO 228
Local display
With
AWG gauge
AWG 20...AWG 14
Scale type
Adjustable differential
Setting
External
Product certifications
CSA
UL
Standards
CE
CSA C22.2 No 14
IEC 60947-5-1
UL 508
Indivisible sale quantity
1
Mechanical durability
8000000 cycles
Cable entry
Cable gland 9-13 mm
Repeat accuracy
2 %
Electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Electrical circuit type
Control circuit
Contacts type and composition
2 C/O
Contacts material
Silver contacts
Terminals description ISO n°1
(13-14-11-12)OF
Terminals description ISO n°2
(23-24-21-22)OF
Auxiliary contacts operation
Simultaneous, snap action
Operating rate
120 cyc/mn
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[In] rated current
3 A, B300, AC-15 (Ue = 120 V) conforming to IEC 60947-5-1, 1.5 A, B300, AC-15 (Ue = 240 V) conforming to IEC 60947-5-1, 0.1 A, R300, DC-13 (Ue = 250 V) conforming to IEC 60947-5-1
Resistance across terminals
25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A
Electrical shock protection class
Class I conforming to IEC 1140, class I conforming to IEC 536, class I conforming to NF C 20-030
Short-circuit protection
10 A cartridge fuse, type gG (gl)
Adjustable range of switching point on rising pressure
0.3000…2.5000 bar
Adjustable range of switching point on falling pressure
0.1700…2.3300 bar
Terminal block type
8 terminals
Possible differential minimum at low setting
0.13 bar (+/- 0.02 bar)
Possible differential minimum at high setting
0.17 bar (+/- 0.03 bar)
Height
113 mm
Width
46 mm
Depth
85 mm
Product weight
0.995 kg
IP degree of protection
IP66 conforming to IEC 60529
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Shock resistance
50 gn conforming to IEC 60068-2-27
Vibration resistance
4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz)
Protective treatment
TC standard version
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
CZ (Czech Republic)
MA (Morocco)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916026489
Package 1 height
10.5 cm
Package 1 width
4.5 cm
Package 1 length
15 cm
Package 1 weight
0.995 kg
Unit type of package 2
S01
Number of units in package 2
3
New Package 2 GTIN 14
13666916026486
Package 2 height
15 cm
Package 2 width
15 cm
Package 2 length
40 cm
Package 2 weight
4.623 kg
Unit type of package 3
S02
Number of units in package 3
13
New Package 3 GTIN 14
23666916026483
Package 3 height
15 cm
Package 3 width
30 cm
Package 3 length
40 cm

Expand all

Technical Drawings

Dimensions

epds
  • (1) 1 fluid entry, tapped G1/4 (BSP female)
  • (2) 1 electrical connections entry, tapped Pg 13.5
  • Ø : 2 elongated holes Ø 10.2 x 5.2

Wiring Diagram

Terminal Model

epds

Operating Curves

epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential
epds
  • (y) Rising pressure
  • (x) Falling pressure
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • PH : High point
  • PB : Below point

Expand all

Documents & Downloads

Document name
Date
Size

Expand all

Related products & accessories

Back to top

arrow