XMLG001D21SAL

Electronic pressure sensors, Pressure sensors XM, switch with setting at 0, 7.25 p

arrow

Commercialized

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLG
Pressure rating
1 bar
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
Controlled fluid
Air (-15…125 °C)
Corrosive fluid (-15…125 °C)
Hydraulic oil (-15…125 °C)
Fresh water (0…125 °C)
Type of output signal
Analogue
Analogue output function
4...20 mA, 2 wires
Electrical connection
1 male connector M12, 3 pins
[Us] rated supply voltage
12 V DC (voltage limits: 8…33 V)
24 V DC (voltage limits: 8…33 V)
Quantity per set
Set of 1
Type of packing
Individual
Diameter
22.8 mm
Pressure setting range
0…1 bar
Maximum permissible accidental pressure
2.7 bar
Destruction pressure
3 bar
Local display
Without
Electrical circuit type
Control circuit
Current consumption
< 20 mA
Materials in contact with fluid
Stainless steel type AISI 303
Ceramic
FPM (Viton)
Operating position
Any position
Protection type
Reverse polarity
Load short-circuit
Surge withstand
1 kV 42 Ohm conforming to IEC 61000-4-5
500 kV 12 Ohm conforming to IEC 61000-4-5
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
< 2 ms
Drift of the sensitivity
+/- 0.015 % of measuring range/°C
Drift of the zero point
+/- 0.015 % of measuring range/°C
Measurement accuracy
+/- 0.3 % of the measuring range
Repeat accuracy
+/- 0.1 % of the measuring range
Mechanical durability
10000000 cycles
Net weight
0.095 kg
Height
58.1 mm
Length
48.5 mm
Standards
CE
IEC 61326-2-3
Product certifications
UL 508
CSA C22.2 No 14
Protective treatment
TC
Ambient air temperature for operation
-15…85 °C
Ambient air temperature for storage
-40…85 °C
Vibration resistance
20 gn (f= 9…2000 Hz) conforming to IEC 60028-2-6
Shock resistance
25 gn for 11 ms conforming to IEC 60068-2-27
Resistance to electrostatic discharge
15 kV in air conforming to IEC 61000-4-2
8 kV on contact conforming to IEC 61000-4-2
Resistance to electromagnetic fields
200 V/m 80…1000 Hz conforming to IEC 61000-4-3
Resistance to fast transients
4 kV conforming to IEC 61000-4-4
Resistance to conducted disturbances
30 V (0.15…80 Hz) conforming to IEC 61000-4-6
Resistance to magnetic fields
30 A/m 50 Hz conforming to IEC 61000-4-8
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
NEMA degree of protection
NEMA 4
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
5.0 cm
Package 1 Width
10.5 cm
Package 1 Length
13.5 cm
Package 1 Weight
136.0 g
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov