Pressure setting range
0.0000000000…1034.2 kPa
Maximum permissible accidental pressure
2068.4 kPa
Destruction pressure
3102.6 kPa
Materials in contact with fluid
Stainless steel type AISI 303
Ceramic
Nitrile (NBR)
Operating position
Any position
Protection type
Reverse polarity
Load short-circuit
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 6 kV contact
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm
Radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz
Immunity to magnetic fields conforming to IEC 61000-4-8 30 A/m 50 Hz
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
< 5 ms
Measurement accuracy
+/- 1 % of the measuring range
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0.04 % of measuring range/°K
Drift of the zero point
+/- 0.03 % of measuring range/°K
Repeat accuracy
+/- 1 % of the measuring range
Mechanical durability
10000000 cycles
Scale type
Fixed differential