Pressure setting range
0…10 bar
Maximum permissible accidental pressure
30 bar
Destruction pressure
60 bar
Materials in contact with fluid
Fluorocarbon FPM
Stainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuit
Reverse polarity
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm
Immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...3000 MHz
Radiated RF fields conforming to IEC 61000-4-6 10 V 0.01...80 MHz
[Uimp] rated impulse withstand voltage
0.5 kV
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0.5 % of the measuring range
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0.02 % of measuring range/°K
Drift of the zero point
+/- 0.02 % of measuring range/°K
Mechanical durability
10000000 cycles