XMLP160BD21F

Electronic pressure sensors, Pressure sensors XM, transmitter, XMLP, 160 bar, G1/4 A male, 4...20 mA, M12, set of 1

arrow

Commercialised

Expand all

Datasheet

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLP
Electrical circuit type
Control circuit
Local display
Without
Controlled fluid
Air (-30-135 °C), fresh water (0-135 °C), hydraulic oil (-30-135 °C), gas (-30-135 °C), refrigeration fluid (-30-135 °C)
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
Electrical connection
1 male connector M12 4 pins
[Us] rated supply voltage
12...24 V DC SELV (voltage limits: 7-33 V)
Current consumption
< 23 mA
Type of output signal
Analogue
Analogue output function
4...20 mA, 2-wire
Quantity per set
Set of 1
Type of packing
Individual
Materials in contact with fluid
Fluorocarbon FPM
stainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuit
reverse polarity
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 4 kV, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...3000 MHz, radiated RF fields conforming to IEC 61000-4-6 10 V 0.01...80 MHz
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0,5 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K
Standards
IEC 61326-2-3
NSF ANSI 61
Product certifications
CE
cULus
RCM
Protective treatment
TC
Vibration resistance
20 gn (f = 15-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529, IP67 conforming to IEC 60529, IP69K conforming to IEC 60529
Unit type of package 1
PCE
Number of units in package 1
1
Unit type of package 2
S01
Number of units in package 2
24
Package 2 height
15 CENTIMETER
Package 2 width
15 CENTIMETER
Package 2 length
40 CENTIMETER
Package 2 weight
2.556 KILOGRAM
Indivisible sale quantity
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expand all

Technical Drawings

Dimensions

epds
  • (1) SW24 tightening torque ≤ 25 N.m / 221 lb-in

Wiring Diagram

2-Wire Technique (4-20 mA)

epds
  • (a) I out

Curves

epds

Expand all

Documents & Downloads

Document name
Date
Size
Document name
Date
Size

Expand all

Related products & accessories

img
XMLZL016

Sealing gasket, for pressure sensor XMLP, set of 10 pieces

img
XZCC12FCM40B

Female, M12, 4 pin, elbowed connector, cable gland Pg 7

img
XZCC12FDM40B

Female, M12, 4 pin, straight connector, cable gland Pg 7

img
XZCP1141L2

Pre wired connectors XZ, straight female, M12, 4 pins, cable PUR 2 m

img
XZCP1241L2

Pre wired connectors XZ, elbowed female, M12, 4 pins, cable PUR 2 m

Back to top

arrow