Current consumption
<= 50 mA
Electrical connection
Male connector M12, 4 pins
Analogue output function
0...10 V
Type of output signal
Analogue + discrete
Analogue output function
0...10 V
Discrete output type
Solid state PNP, NO/NC programmable
Maximum switching current
250 mA
Contacts type and composition
NO/NC programmable
Scale type
Fixed differential
Adjustable range of switching point on rising pressure
2…25 MPa
20…250 bar
1999.48…24993.49 kPa
Adjustable range of switching point on falling pressure
1247.95…24241.97 kPa
12.5…242 bar
1.25…24.2 MPa
Minimum differential travel
0.75 MPa
751.53 kPa
7.5 bar
Materials in contact with fluid
316L stainless steel
Housing material
316L stainless steel
Polyacrylamide
Operating position
Any position, but disposals can falsified the measurement in case of upside down mounting
Protection type
Short-circuit protection
Overvoltage protection
Overload protection
Reverse polarity
Response time on output
<= 10 ms for analog output
<= 5 ms for discrete output
Time delay range
0...50 s in steps of 1 second
Display type
4 digits 7 segments
Local signalling
1 LED (yellow) for light ON when switch is actuated
Display response time type
Fast 50 ms
Normal 200 ms
Slow 600 ms
Maximum delay first up
300 ms
Accuracy
<= 1 % of the measuring range
Linearity error
<= 0.5 % of the measuring range
Hysteresis
<= 0.2 % of the measuring range
Measurement accuracy
<= 0.6 % of the measuring range
Repeat accuracy
<= 0.2 % of the measuring range
Drift of the sensitivity
+/- 0.03 % of measuring range/°C
Drift of the zero point
+/- 0.1 % of measuring range/°C
Display accuracy
<= 1 % of the measuring range
Mechanical durability
10000000 cycles
[Uimp] rated impulse withstand voltage
0.5 kV DC
Electromagnetic compatibility
Susceptibility to electromagnetic fields: 10 V/m 80...2000 MHz conforming to IEC 61000-4-3
Immunity to conducted RF disturbances: 10 V 0.15...80 MHz conforming to IEC 61000-4-6
Surge immunity test: 1 kV conforming to IEC 61000-4-5
Electrical fast transient/burst immunity test: 2 kV conforming to IEC 61000-4-4
Electrostatic discharge immunity test: 8 kV air, 4 kV contact conforming to IEC 61000-4-2