SIL 2 conforming to IEC 61508, PL = d conforming to ISO 13849-1, SILCL 2 conforming to IEC 62061
Safety reliability data
MTTFd = 1546 years, PFHd = 7.4E-8 1/h, SFF = 92 %, DC = 75 % with appropriate safety controller
[Sn] nominal sensing distance
20 mm
Wiring technique
4-wire
Detector flush mounting acceptance
Flush mountable
Delay response
1.2 ms
Product certifications
CCC CSA E2 TÜV UL
Marking
CE
Indivisible sale quantity
1
Sensing range
> 15...40 mm
Cable entry number
1 tapped entry for M20 x 1.5 cable gland
Repeat accuracy
<= 3% of Sr
Electrical connection
Screw-clamp terminals, 4 x 1.5 mm²
Supply voltage limits
10-58 V DC
[Us] rated supply voltage
12...48 V DC with reverse polarity protection
Switching capacity in mA
<= 200 mA with overload and short-circuit protection
Voltage drop
<2 V (closed)
Current consumption
0...15 mA no-load
Status LED
Supply on: 1 LED (green), output state: 1 LED (yellow)
Output circuit type
DC
Type of output signal
Discrete
Detection face
5 positions turret head
Discrete output type
PNP
Discrete output function
1 NO + 1 NC
Switching frequency
<= 300 Hz
Differential travel
3...15% of Sr
Delay first up
7.5 ms
Delay recovery
1.8 ms
Height
40 mm
Width
117 mm
Length
40 mm
Size
117 mm
Product weight
0.244 kg
IP degree of protection
IP67 conforming to IEC 60529, IP65 conforming to IEC 60529, IP69K conforming to DIN 40050
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…85 °C
Shock resistance
50 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
25 gn amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov