Detection system
Transmitter-receiver system
Kit composition
adjustable mounting bracket(s)
1 receiver(s)
1 transmitter(s)
1 user guide with certificate of conformity on CD-ROM
[EAA] effective aperture angle
2.5 ° at 3 m
[Us] rated supply voltage
24 V DC +/- 20 %
Supply
Power supply conforming to IEC 61496-1
Power supply conforming to IEC 60204-1
[Ie] rated operational current
2 A
Current consumption
42 mA no-load transmitter
83 mA no-load receiver
42 mA transmitter
900 mA with maximum load receiver
Output current limits
0.4 A for safety outputs OSSD
Maximum voltage drop
<0.5 V
Local signalling
1 multi-colour LED transmitter
2 dual colour LEDs receiver
Electrical connection
1 male connector M12 5 pins transmitter
1 male connector M12 8 pins receiver
Function available
Test
Muting through external safety module XPSLCMUT1160
LED display of operating modes and faults
Material
Aluminium: casing
Polycarbonate: front panel
Polypropylene: end caps
Housing colour
Red RAL 3000
Fixing mode
By fixing brackets
Offer type
Standard distance
Topology
Daisy chain slave1