XX2V3A1PFM12

Ultrasonic sensors XX, ultrasonic dual level sensor 2 NO 4 wires m30

arrow

Commercialized

green premium

Expand all

Datasheet

Range of product
Telemecanique Ultrasonic sensors XX
Sensor type
Ultrasonic sensor
Series name
General purpose
Sensor name
XX2
Sensor design
Cylindrical M30
Detection system
Diffuse
[Sn] nominal sensing distance
8 m adjustable with teach push-button
Material
Plastic
Type of output signal
Discrete
Discrete output function
2 NO
Wiring technique
4-wire
Discrete output type
PNP
[Us] rated supply voltage
12...24 V DC with reverse polarity protection
Electrical connection
Male connector M12 4 pins
Product specific application
For 2 levels monitoring
[Sd] sensing range
0.3…8 m
Beam angle
16 °
IP degree of protection
IP67 conforming to IEC 60529
Enclosure material
ULTEM
Front material
Silicone
Thread type
M30 x 1.5
Supply voltage limits
10…28 V DC
Function available
Without synchronisation mode
[Sa] assured operating distance
0.3…8 m (teach mode)
Maximum differential travel
12.7 mm
Blind zone
0…300 mm
Transmission frequency
75 kHz
Repeat accuracy
2.54 %
Deviation angle from 90° of object to be detected
-5…5 °
Minimum size of detected object
Cylinder diameter 50.8 mm at 4.732 m
Status LED
Output state: 1 LED (green/red (flashing))
Setting-up assistance: 1 LED (green/red (flashing))
Distance indication: 1 LED (yellow)
Current consumption
100 mA
Maximum switching current
100 mA with overload and short-circuit protection
Maximum voltage drop
1 V
Maximum delay first up
1000 ms
Maximum delay response
150 ms
Maximum delay recovery
1000 ms
Marking
CE
Threaded length
64.3 mm
Height
44 mm
Width
44 mm
Depth
118 mm
Net weight
0.11 kg
Standards
IEC 60947-5-2
Product certifications
UL
cCSAus
Ambient air temperature for operation
-20…60 °C
Ambient air temperature for storage
-10…80 °C
Vibration resistance
+/-1 mm conforming to IEC 60068-2-6 (f = 10…55 Hz)
Shock resistance
30 gn in all 3 axes for 11 ms conforming to IEC 60068-2-27
Resistance to electrostatic discharge
8 kV level 4 conforming to IEC 61000-4-2
Resistance to electromagnetic fields
10 V/m level 3 conforming to IEC 61000-4-3
Resistance to fast transients
1 kV level 3 conforming to IEC 61000-4-4
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.7 cm
Package 1 Width
7.7 cm
Package 1 Length
15.5 cm
Package 1 Weight
90.719 g
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Expand all

Documents & Downloads

Document name
Date
Size

Back to top

arrow