Local signalling
Without pilot light
Cover material
Stainless steel
Reset
By mushroom head push-button
Contacts type and composition
2 NC + 1 NO
Contact operation
Slow-break
Trigger cable anchor point
RH or LH side
Connections - terminals
Screw clamp terminal, 1 x 0.34...1 x 1 mm², screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data
B10d = 4000000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
Positive opening
With conforming to IEC 60947-5-1
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3, 25 MOhm conforming to NF C 93-050 method A
Terminals description ISO n°1
(13-14)NO
(21-22)NC
(31-32)NC