Latching emergency stop rope pull switch XY2CJ, LH side, 1NC+1NO, Pg13.5

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Emergency stop rope pull switches XY2C
Product or component type
Latching emergency stop rope pull switch
Device short name
XY2C
ETIM classification
ETIM 9 - EC002033 - Emergency stop pull cord switch
Cover material
Galvanised steel
Body material
Zamak
Housing colour
Red RAL 3000
Safety level
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach category 4 with the appropriate monitoring system and correctly wired conforming to EN/ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to EN/IEC 61508
Safety reliability data
B10d = 500000 conforming to IEC 60947-5-5 value given for a life time of 20 years limited by mechanical or contact wear
Trigger cable maximum length
30 m
Trigger cable anchor point
LH side
Number of cables
1
Product certifications
UL category NISD emergency stop devices, CSA, CCC, EAC
Marking
CE
Standards
CSA C22.2 No 14
IEC 60204-1
IEC 60947-5-1
IEC 60947-5-5
ISO 13850
machinery directive 2006/42/EC
UL 508
work equipment directive 2009/104/EC
Indivisible sale quantity
1
Mechanical durability
100000 cycles
Reset
By pull button
Cable entry number
1 tapped entry for Pg 13.5 cable gland
Contacts type and composition
1 NC + 1 NO
Terminals description ISO n°1
(13-14)NO
(21-22)NC
Contact operation
Slow-break
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
500 V (pollution degree 3) conforming to IEC 60947-1, 300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14
Overvoltage category
Class I conforming to IEC 61140
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1 appendix A, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
Resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3, 25 MOhm conforming to NF C 93-050 method A
Short-circuit protection
10 A cartridge fuse type gG conforming to IEC 60269
Local signalling
Color indicator
Connections - terminals
Screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Positive opening
With conforming to IEC 60947-5-1
Product weight
0.669 kg
IP degree of protection
IP66 conforming to IEC 60529, IP67 conforming to IEC 60529
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Shock resistance
50 gn 11 ms conforming to IEC 60068-2-27
Vibration resistance
10 gn (f= 10-150 Hz) conforming to IEC 60068-2-6
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
ID (Indonesia)
Unit type of package 1
PCE
Number of units in package 1
1
New Package 1 GTIN-13
3666916064375
Package 1 height
9 cm
Package 1 width
16 cm
Package 1 length
20.3 cm
Package 1 weight
0.669 kg
Unit type of package 2
S03
Number of units in package 2
6
New Package 2 GTIN 14
13666916064372
Package 2 height
30 cm
Package 2 width
30 cm
Package 2 length
40 cm
Package 2 weight
5.453 kg
Unit type of package 3
CAR
Number of units in package 3
1
New Package 3 GTIN 14
23666916064379
Package 3 height
9 cm
Package 3 width
16 cm
Package 3 length
20.3 cm
Package 3 weight
0.79 kg

Expand all

Technical Drawings

Dimensions

epds
  • (1) Tapped entries for Pg 13.5 cable gland
  • (2) Maximum extension.

Electrical Curves

AC Supply 50/60 Hz Inductive Circuit

epds
  • Y Millions of operating cycles
  • X Current in A

Electrical Curves

Expand all

Documents & Downloads

Document name
Date
Size

Back to top

arrow