XGCS4901201S02

OSITRACK COMPACT STATION FORMAT C - 13 MHZ

End of commercialisation End of commercialization date : January 04th 2022 End of service date : January 04th 2022

Expand all

Datasheet

Range of product
Telemecanique Radio frequency identification XG
Product or component type
Compact smart antenna
RFID compact station name
XGCS
Design
Flat form 40 x 40 x 15
Electrical connection
5 pin(s)male remote connector M12, shielded cable cable 0.2 m
Outer dimension
40 x 40 x 15 mm
Product compatibility
RFID microchip Fujitsu (MB89R118 - MB89R119)
RFID microchip INSIDE (micropass)
RFID microchip Microelectronic (EM4135)
RFID microchip STM (CRIX4K)
RFID microchip NXP (SL2, SL1, Ultralight, Std 1K/4K, Desfire)
RFID microchip Texas (Tag-it HFI)
[Us] rated supply voltage
24 V DC conforming to Protective Extra Low Voltage
Transmission rate
9600 bauds...115200 bauds (automatic detection)
Communication port protocol
Modbus RTU
Uni-Telway
Communication port support
RS485
Associated tag type
Automatic detection of the type of tags
ISO 14443 standard tags
ISO 15693 standard tags
Current consumption
< 60 mA
Status LED
Communication network: 1 LED (dual colour), RFID communication: 1 LED (dual colour)
Tightening torque
< 1 N.m
Marking
CE
Product certifications
UL, FCC
Standards
ETSI EN 300 330-1
ETSI EN 300 330-2
ETSI EN 301 489-1
ETSI EN 301 489-3
IP degree of protection
IP65 conforming to IEC 60529
Vibration resistance
2 mm (f= 5-29.5 Hz) conforming to IEC 60068-2-6, 7 gn (f= 29.5-150 Hz) conforming to IEC 60068-2-6
Shock resistance
30 gn for 11 ms conforming to IEC 60068-2-27
IK degree of protection
IK02 conforming to IEC 62262
Electromagnetic compatibility
Electrostatic discharge immunity test: (contact discharge), 3, 6 kV, conforming to IEC 61000-4-2, electrostatic discharge immunity test: (air discharge), 3, 8 kV, conforming to IEC 61000-4-2, electrical fast transient/burst immunity test: (signal ports), 3, 1 kV, conforming to IEC 61000-4-4, electrical fast transient/burst immunity test: (power ports), 3, 2 kV, conforming to IEC 61000-4-4, susceptibility to electromagnetic fields: , 3, 10 V/m, conforming to IEC 61000-4-3, 1.2/50 µs shock waves immunity test: , 3, 10 kV, conforming to IEC 61000-4-5, conducted RF disturbances: , 3, 10 V, conforming to IEC 61000-4-6, magnetic field at power frequency: , 4, 30 A/m, conforming to IEC 61000-4-8
Unit type of package 1
PCE
Number of units in package 1
1
Package 1 height
6.6 CENTIMETER
Package 1 width
9.4 CENTIMETER
Package 1 length
13 CENTIMETER
Package 1 weight
350 GRAM
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov