Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1
Can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
Ambient air temperature for operation
-25…85 °C
Ambient air temperature for storage
-40…85 °C
Vibration resistance
10 gn (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance
30 gn for 11 ms conforming to IEC 60068-2-27
Maximum sensitivity to magnetic fields
0.3 mT
Electrical shock protection class
Class II conforming to IEC 60536
IP degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
Enclosure material
Thermoplastic PBT
Dust zone
According to protection mode mD, tD and ia
Zone 0 - 1 - 2/20 - 21 - 22
Product certifications
INERIS 07ATEX0036
Standards
IEC 60079-0
EN 60079-11
EN 60079-18
IEC 60079-31
ISO 13849-1
Directives
2014/34/EU - ATEX directive