Controlled fluid
Air (0-80 °C), fresh water (0-80 °C)
Current consumption
20 mA
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 6 kV contact, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, immunity to magnetic fields conforming to IEC 61000-4-8 30 A/m 50 Hz
Protection type
Load short-circuit
reverse polarity
Response time on output
< 5 ms
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,04 % of measuring range/°K
Drift of the zero point
+/- 0,03 % of measuring range/°K
Repeat accuracy
+/- 1 % de la plage de mesure
Measurement accuracy
+/- 1 % de la plage de mesure