Minimum actuation speed
0.01 m/mn
Electrical durability
5000000 cycles, DC-13 120 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13 24 V, 4 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13 48 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical connection
Remote male connector 7/8", 5 pins
Wire insulation material
PvR
Positive opening
With, conforming to IEC 60947-5-1 Annex K
Contacts insulation form
Zb
Contacts type and composition
1 NC + 1 NO
Contacts material
Silver plated contacts
Contact operation
Snap action
[Uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60664, 2.5 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V (pollution degree 3) conforming to UL 508, 300 V (pollution degree 3) conforming to CSA C22.2 No 14, 250 V (pollution degree 3) conforming to IEC 60947-5-1
[Ie] rated operational current
1.5 A at 240 V, AC-15, B300 conforming to IEC 60947-5-1 appendix A, 0.1 A at 250 V, DC-13, R300 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
6 A
Resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
Short-circuit protection
6 A cartridge fuse, type gG