Minimum actuation speed
0.01 m/mn
Electrical durability
5000000 cycles, DC-13 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C, 5000000 cycles, DC-13 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Electrical connection
Male connector M12, 4 pins
Contacts insulation form
Za
Contacts type and composition
1 C/O
Contacts material
Gold plated contacts
Contact operation
Snap action
[Uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60664, 2.5 kV conforming to IEC 60947-1
[Ui] rated insulation voltage
300 V (pollution degree 3) conforming to UL 508, 300 V (pollution degree 3) conforming to CSA C22.2 No 14, 250 V (pollution degree 3) conforming to IEC 60947-5-1
[Ie] rated operational current
0.1 A at 250 V, DC-13 conforming to IEC 60947-5-1 appendix A, 1.5 A at 240 V, AC-15 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
3 A
Resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
Short-circuit protection
4 A cartridge fuse, type gG