9012GFW3G17

Pressure switch 9012G, fixed scale - 1 threshold - 170 to 5600 PSIG psig

End of commercialisation Fecha de fin de comercialización : Fecha de fin del servicio :

Expandir todo

Ficha de datos

Range of product
9012G
Pressure sensor type
Electromechanical pressure switch
Pressure sensor name
9012G
Maximum pressure
20000 psi
Contacts type and composition
NC-NO, 2 SPDT-DB, Form Z, snap action, silver nickel contacts
Controlled fluid
Hydraulic oil (-15-250 °F), non-corrosive liquids, air, non-corrosive gas
Fluid connection type
0.25 inch 18 NPTF conforming to UL 508
Pressure switch type of operation
Detection of 1 single threshold
Scale type
Fixed
Local display
Without
Cable entry
0.5 inch NPT conduit entrance
Terminal block type
4 screw terminals
Electrical connection
Screw-clamp terminals, AWG 22...AWG 12
Terminal identifier
(1-5)NC
(3)gnd
Electrical circuit type
Control circuit
Local signalling
1 neon: (clear) 120 V AC/DC (105...125 V)
Setting
Internal
Enclosure material
Die cast aluminium alloy 380
Pressure actuator
Piston
Operating position
Any position
Materials in contact with fluid
303 stainless steel
zinc plated steel
Operating rate
120 cyc/mn
Vibration resistance
2 gn (f= 40-150 Hz) conforming to IEC 68-2-6
Shock resistance
50 gn conforming to IEC 58-2-27
Standards
CE
UL 508
Product certifications
CSA LR25490 class 3211 03
UL listed file E12158 CCN NKPZ and CCN NTHT
UL listed file E12158 CCN NKPZ
NEMA degree of protection
NEMA 4/4X/13 conforming to UL 50
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov