XMLK006B2D71TQ

Pressure sensor XMLK - 0..6bar - G 1/4A - 0..10V - M12 - set of 25

End of commercialisation Fecha de fin de comercialización : January 12th 2022 Fecha de fin del servicio : January 12th 2022

XMLK006B2D71TQ is replaced by the following product:

img
XMLP006GD71F

Electronic pressure sensors, Pressure sensors XM, transmitter 6 bar, 0...10 V, G1/4 A male, FPM, M12

Quantity :  1

Expandir todo

Ficha de datos

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electronic pressure sensors
Pressure sensor type
Pressure transmitter
Pressure sensor name
XMLK
Fluid connection type
G 1/4A (male) conforming to DIN 3852-E
Electrical circuit type
Control circuit
Electrical connection
1 male connector M12 4 pins
Type of output signal
Analogue
[Us] rated supply voltage
24 V DC SELV (voltage limits: 16.2-33 V)
Analogue output function
0...10 V, 3-wire
Quantity per set
Set of 25
Type of packing
Group
Materials in contact with fluid
Ceramic
nitrile (NBR)
stainless steel type AISI 303
Controlled fluid
Air (0-80 °C), fresh water (0-80 °C)
Local display
Without
Current consumption
< 6 mA
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 6 kV contact, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...1000 MHz, electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 500 V 12 Ohm, 1 kV 42 Ohm, radiated RF fields conforming to IEC 61000-4-6 10 V 0.15...80 MHz, immunity to magnetic fields conforming to IEC 61000-4-8 30 A/m 50 Hz
Protection type
Load short-circuit
reverse polarity
Response time on output
< 5 ms
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,04 % of measuring range/°K
Drift of the zero point
+/- 0,03 % of measuring range/°K
Repeat accuracy
+/- 1 % de la plage de mesure
Measurement accuracy
+/- 1 % de la plage de mesure
Operating position
Any position
Standards
CE
IEC 61326-2-3
Product certifications
CSA C22-2 No 14
RCM
UL 508
Protective treatment
TC
Vibration resistance
20 gn (f = 9-2000 Hz) conforming to IEC 60068-2-6
Shock resistance
25 gn for 11 ms conforming to IEC 60068-2-27
IP degree of protection
IP65 conforming to IEC 60529
NEMA degree of protection
NEMA 4
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. Fo more information go to www.P65Warnings.ca.gov

Expandir todo

Dibujos tecnicos

Dimensions

epds

Wiring Diagram

3-Wire Technique (0-10 V)

epds
  • (a) V out

Output Curves

epds

Back to top