9012GAWM25

Pressure switch 9012G, adjustable scale, 2 thresholds, 3.0 to 150 PSIG

End of commercialisation End of commercialization date : April 20th 2022 End of service date : April 20th 2022

Expand all

Datasheet

Range of product
9012G
Pressure sensor type
Electromechanical pressure switch
Pressure sensor name
9012G
Maximum pressure
475 psi
Contacts type and composition
2(NC-NO), DPDT-DB, Form ZZ, snap action, silver nickel contacts
Controlled fluid
Hydraulic oil (-40-250 °F), selected corrosive gases, air, non-corrosive gas
Fluid connection type
0.25 inch BS2779 parallel pipe thread conforming to UL 508
Pressure switch type of operation
Regulation between 2 thresholds
Scale type
Adjustable differential
Local display
Without
Cable entry
20 mm BS4568 conduit entrance
Terminal block type
8 screw terminals
Electrical connection
Screw-clamp terminals, AWG 22...AWG 12
Electrical circuit type
Control circuit
Local signalling
Without:
Setting
Internal
Enclosure material
Die cast aluminium alloy 380
Pressure actuator
Diaphragm nitrile (Buna-N)
Operating position
Any position
Materials in contact with fluid
Nitrile (Buna-N)
Viton fluorocarbon
Operating rate
120 cyc/mn
Vibration resistance
2 gn (f= 40-150 Hz) conforming to IEC 68-2-6
Shock resistance
50 gn conforming to IEC 58-2-27
Standards
CE
CSA C22.2 No 14
UL 508
Product certifications
CSA LR25490 class 3211 03
UL listed file E12158 CCN NKPZ and CCN NTHT
NEMA degree of protection
NEMA 4/4X/13 conforming to UL 50
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov