Terminal, clamping capacity: 1 x 0.34...2 x 1.5 mm²
Locking options description
WITHOUT LOCKING OF ACTUATOR
Insulation
DOUBLE INSULATED
Positive opening
WITH NC CONTACT
Operating rate
10 cyc/mn for maximum durability
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1,
can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1,
can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Body material
PA
Head material
PA
Standards
CSA C22 2 NO 14 EN 1088 ISO 14119 IEC 60204 1 IEC 60947 5 1 ISO 12100 UL 508
Product certifications
CSA UL
Protective treatment
TC
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Electrical shock protection class
Class II conforming to IEC 61140
IP degree of protection
IP67 conforming to IEC 60529,
IP67 conforming to IEC 60947-5-1
California proposition 65 ATS_CALIFORNIA_PROPOSITION_65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov