XCSPA691

Safety switch XCSPA, plastic, 1NC+1NO, slow break, 1 entry tapped Pg 11

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Safety switch
Component name
XCSPA
Design
Compact
Sensor design
Compact
ETIM classification
ETIM 9 - EC002592 - Position switch with separate actuator
Head type
Key operated turret head
Material
Plastic
Body material
PA (polyamide)
Head material
PA (polyamide)
Number of poles
2
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Locking options description
Without locking of actuator
Product certifications
CSA
UL
Standards
CSA C22.2 No 14
EN 1088/ISO 14119
IEC 60204-1
IEC 60947-5-1
ISO 12100
UL 508
Indivisible sale quantity
1
Actuator forcible withdrawal rtc
10 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
1 entry tapped for Pg 11
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Positive opening
With NC contact
Positive opening minimum force
15 N
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, make before break
Operating rate
10 cyc/mn for maximum durability
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ie] rated operational current
6 A at 120 V, AC-15, A300 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
10 A
Electrical shock protection class
Class II conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Insulation
Double insulated
Width
30 mm
Depth
30 mm
Product weight
0.11 kg
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient air temperature for operation
-13…158 °F
Ambient air temperature for storage
-40…158 °F
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
FR (France)
Unit type of package 1
PCE
Number of units in package 1
1
3666916047217
Package 1 height
3.5 cm
Package 1 width
13.2 cm
Package 1 length
5 cm
Package 1 weight
0.112 kg
Unit type of package 2
S02
Number of units in package 2
30
13666916047214
Package 2 height
15 cm
Package 2 width
30 cm
Package 2 length
40 cm
Package 2 weight
3.764 kg
Unit type of package 3
CAR
Number of units in package 3
1
23666916047211
Package 3 height
5 cm
Package 3 width
3.5 cm
Package 3 length
13.2 cm
Package 3 weight
0.112 kg