Actuator forcible withdrawal rtc
10 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
1 entry tapped for Pg 11
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Positive opening
With NC contact
Positive opening minimum force
15 N
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, make before break
Operating rate
10 cyc/mn for maximum durability
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ie] rated operational current
6 A at 120 V, AC-15, A300 conforming to IEC 60947-5-1, 3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1, 0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
10 A
Electrical shock protection class
Class II conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Insulation
Double insulated