XCSTE5342

Safety interlock XCSTE, plastic, 1NC+1NO, operating key, solenoid

arrow

COMMERCIALISED

Expand all

Datasheet

Range of product
Telemecanique Safety switches XCS
Product or component type
Safety switch
Component name
XCSTE
Design
Rectangular
Sensor design
RECTANGULAR
ETIM classification
ETIM 9 - EC002593 - Position switch with guard locking
Head type
Key operated turret head
Material
Plastic
Body material
PA (polyamide)
Head material
PA (polyamide)
Number of poles
2
Safety level
Can reach category 4 with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach PL = e with the appropriate monitoring system and correctly wired conforming to ISO 13849-1, can reach SIL 3 with the appropriate monitoring system and correctly wired conforming to IEC 61508
Safety reliability data
B10d = 5000000 value given for a life time of 20 years limited by mechanical or contact wear
Locking options description
With interlocking, locking by solenoid
Electromagnet interlocking
Locking on de-energisation and unlocking on energisation of solenoid
Product certifications
CSA
UL
Standards
CSA C22.2 No 14
EN 1088/ISO 14119
IEC 60204-1
IEC 60947-5-1
ISO 12100
UL 508
Indivisible sale quantity
1
Actuator forcible withdrawal rtc
500 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
1 entry tapped for Pg 11
Electrical connection
Terminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Positive opening
With NC contact
Positive opening minimum force
15 N
Contacts type and composition
1 NC + 1 NO
Solenoid contacts type and composition
1 NC (slow-break)
Contact operation
Slow-break, break before make
Operating rate
10 cyc/mn for maximum durability
[Us] rated supply voltage
230 V - 20...10 %
Supply voltage type
AC/DC
Supply frequency
50/60 Hz
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-5-1
[Ui] rated insulation voltage
300 V conforming to UL 508, 500 V conforming to IEC 60947-1, 300 V conforming to CSA C22.2 No 14
[Ie] rated operational current
0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1, 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1, 3 A at 120 V, AC-15, B300 conforming to IEC 60947-5-1, 1.5 A at 240 V, AC-15, B300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
6 A
Power consumption in VA
10 VA
Electrical shock protection class
Class II conforming to IEC 61140
Short-circuit protection
10 A cartridge fuse type gG (gl)
Insulation
Double insulated
Width
110 mm
Depth
33 mm
Product weight
0.36 kg
IP degree of protection
IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Ambient air temperature for operation
-13…140 °F
Ambient air temperature for storage
-40…158 °F
Shock resistance
10 gn for 11 ms conforming to IEC 60068-2-27
Vibration resistance
5 gn (f= 10-500 Hz) conforming to IEC 60068-2-6
Protective treatment
TC
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty
18 months
Country of origin
FR (France)
Unit type of package 1
PCE
Number of units in package 1
1
3666916046937
Package 1 height
4 cm
Package 1 width
11.5 cm
Package 1 length
10.7 cm
Package 1 weight
0.385 kg
Unit type of package 2
S01
Number of units in package 2
10
13666916046934
Package 2 height
15 cm
Package 2 width
15 cm
Package 2 length
40 cm
Package 2 weight
4.057 kg
Unit type of package 3
S02
Number of units in package 3
18
23666916046931
Package 3 height
15 cm
Package 3 width
30 cm
Package 3 length
40 cm