XS7C40MP230

Inductive sensor XS7 40x40x117 - plastic - Sn15mm - 24..240VAC/DC - terminals

End of commercialisation End of commercialization date : End of service date :

XS7C40MP230 is replaced by the following product:

img
XS7C4A1MPG13

Inductive proximity sensors XS, inductive sensor XS7 40x40x117, PBT, Sn15 mm, 24...240VAC/DC, terminals

Quantity :  1

Expand all

Datasheet

Range of product
Telemecanique Inductive proximity sensors XS
Series name
General purpose
Sensor type
Inductive proximity sensor
Device application
Not applicable
Sensor name
XS7
Sensor design
Form 40 x 40 x 117
Size
117 mm
Body type
Fixed
Type of output signal
Discrete
Wiring technique
2-wire
Enclosure material
Plastic
Discrete output function
1 NO or 1 NC programmable
Electrical connection
Screw-clamp terminals, 2 x 1.5 mm²
[Us] rated supply voltage
24...240 V AC 50/60 Hz, 24...210 V DC
Switching capacity in mA
5...200 mA DC, 5...300 mA AC
IP degree of protection
IP67 conforming to IEC 60529
Detector flush mounting acceptance
Flush mountable
Material
Plastic
Output circuit type
AC/DC
Detection face
5 positions turret head
Sensing range
8...15 mm
Front material
Plastic
Differential travel
3...20% of Sr
Repeat accuracy
<= 3% of Sr
Status LED
Output state: 1 LED (yellow)
Switching frequency
<= 25 Hz AC, <= 50 Hz DC
Residual current
0.8 mA open state 24 V, 1.5 mA open state 120 V
Voltage drop
<5.5 V (closed)
Delay first up
120 MILLISECOND
Delay response
30 MILLISECOND
Marking
CE
Delay recovery
20 MILLISECOND
Product certifications
CCC
CSA
C-Tick
UL
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. Fo more information go to www.P65Warnings.ca.gov

Expand all

Technical Drawings

Dimensions

epds

Setting-up

Minimum Mounting Distances (mm)

epds

Minimum Mounting Distances (mm)

epds

Minimum Mounting Distances (mm)

epds

Wiring Schemes

2-Wire AC or DC Programmable, NO or NC Output Depending on Position of Link

epds

Back to top