XMLD001R1S13

pressure switch XMLD 1 bar - 2 stages fixed scale - 2 C/O

END OF COMMERCIALISATION 下架日期 : August 01st 2023 终止服务日期 : August 01st 2023

XMLD001R1S13 is replaced by the following product:

img

Quantity :  1

展开全部

参数资料

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electromechanical pressure sensor
Pressure sensor type
Electromechanical pressure sensor
Device short name
XMLD
Fluid connection type
1/4" - 18 NPTF (female)
Electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
Electrical circuit type
Control circuit
AWG gauge
AWG 20...AWG 14
Pressure switch type of operation
Detection of 2 single thresholds
Cable entry
Cable gland
Contacts type and composition
2 C/O snap action, silver contacts, 2 C/O staggered, silver contacts
Product specific application
Dual stage
Materials in contact with fluid
304L stainless steel
FPM, FKM
steel
Pressure actuator
Diaphragm
Scale type
Fixed differential
Controlled fluid
Air (0-160 °C), hydraulic oil (0-160 °C)
Local display
Without
Enclosure material
Zinc alloy
Terminal block type
8 terminals
Operating rate
120 cyc/mn
Setting
External
Resistance across terminals
25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A
Terminals description ISO n°1
(13-14-11-12)OF
Operating position
Any position
Standards
CE
CSA C22.2 No 14
IEC 60947-5-1
UL 508
Product certifications
CSA
UL
Protective treatment
TC standard version
IP degree of protection
IP66 conforming to IEC 60529
Vibration resistance
2 gn conforming to IEC 60068-2-6 (f = 30-500 Hz)
Shock resistance
30 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 1140, class I conforming to IEC 536, class I conforming to NF C 20-030
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. Fo more information go to www.P65Warnings.ca.gov

展开全部

技术图纸

Dimensions

epds
  • Ø a = 110 mm / 4.33 in.
  • (1) 1 fluid entry, tapped 1/4" NPTF
  • (2) 1 electrical connections entry, tapped 1/2" NPT

Wiring Diagram

Terminal Model

epds
  • (a) Contact 1
  • (b) Contact 2

Operating Curves

High Setting Tripping Points of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential

Operating Curves

Natural Differential of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Rising pressure
  • (x) Falling pressure
  • EF : Contact 1
  • GH : Contact 2

Natural Differential of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Rising pressure
  • (x) Falling pressure
  • EF : Contact 1
  • GH : Contact 2
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • (2) Non adjustable value
  • PH : High point
  • PB : Below point

Back to top