XMLD160D1S12

Pressure switch XMLD 160 bar - 2 stages fixed scale - 2 C/O

End of commercialisation 下架日期 : April 20th 2022 终止服务日期 : April 20th 2022

展开全部

参数资料

Range of product
Telemecanique Pressure sensors XM
Product or component type
Electromechanical pressure sensor
Pressure sensor type
Electromechanical pressure sensor
Device short name
XMLD
Controlled fluid
Hydraulic oil (0-160 °C)
Fluid connection type
G 1/4 (female) conforming to ISO 228
Electrical connection
Screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
AWG gauge
AWG 20...AWG 14
Cable entry
Cable gland 7-13 mm
Contacts type and composition
2 C/O snap action, silver contacts, 2 C/O staggered, silver contacts
Product specific application
Dual stage
Pressure switch type of operation
Detection of 2 single thresholds
Electrical circuit type
Control circuit
Scale type
Fixed differential
Local display
Without
Pressure actuator
Piston
Materials in contact with fluid
Brass
FPM, FKM
PTFE
steel
Enclosure material
Zinc alloy
Terminal block type
8 terminals
Operating rate
60 cyc/mn
Resistance across terminals
25 mOhm conforming to IEC 255-7 category 3, 25 mOhm conforming to NF C 93-050 method A
Setting
External
Standards
CE
CSA C22.2 No 14
IEC 60947-5-1
UL 508
Product certifications
CSA
UL
Protective treatment
TC standard version
Operating position
Any position
Vibration resistance
4 gn conforming to IEC 60068-2-6 (f = 30-500 Hz)
Shock resistance
50 gn conforming to IEC 60068-2-27
Electrical shock protection class
Class I conforming to IEC 1140, class I conforming to IEC 536, class I conforming to NF C 20-030
IP degree of protection
IP66 conforming to IEC 60529
Unit type of package 1
PCE
Number of units in package 1
1
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

展开全部

技术图纸

Dimensions

epds
  • (1) 1 fluid entry, tapped G1/4 (BSP female)
  • (2) 1 electrical connections entry, tapped M20 x 1.5
  • Ø : 2 elongated holes Ø 5.2 x 6.7

Wiring Diagram

Terminal Model

epds
  • (a) Contact 1
  • (b) Contact 2

Operating Curves

High Setting Tripping Points of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential

Operating Curves

Natural Differential of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Rising pressure
  • (x) Falling pressure
  • EF : Contact 1
  • GH : Contact 2

Natural Differential of Contacts 1 and 2

epds
  • (y) PH2 setting (rising pressure)
  • (x) PH1 setting (rising pressure)
  • 1 : Maximum differential
  • 2 : Minimum differential
  • (y) Rising pressure
  • (x) Falling pressure
  • EF : Contact 1
  • GH : Contact 2
  • (y) Pressure
  • (x) Time
  • (1) Adjustable value
  • (2) Non adjustable value
  • PH : High point
  • PB : Below point

展开全部

文档和下载

文档名称
日期
大小

Back to top

arrow