1 LED (green) for supply on/stability, 1 LED (orange) for output state
Sensing range
0.05...7 m
Maximum voltage drop
<2 V (closed state)no-load
Delay first up
100 MILLISECOND
Delay recovery
0.5 MILLISECOND
Shock resistance
30 gn (duration = 11 ms) for for every axis conforming to IEC 60068-2-27
IP degree of protection
IP67 conforming to IEC 60529, IP65 conforming to IEC 60529
Vibration resistance
7 gn, amplitude = +/- 1.5 mm (f = 10-55 Hz)for every axis conforming to IEC 60068-2-6
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. Fo more information go to www.P65Warnings.ca.gov