Actuator forcible withdrawal rtc
3000 N
Actuator force for extraction
20 N
Mechanical durability
1000000 cycles
Minimum actuation speed
0.01 m/s
Cable entry
3 entries tapped for M20 x 1.5
Electrical connection
Spring terminal, clamping capacity: 1 x 1.5 mm² flexible or solid cable, spring terminal, clamping capacity: 2 x 0.5 mm² flexible cables with 13 mm bared ends
Positive opening
With NC contact
Contacts type and composition
2 NC + 1 NO
Solenoid contacts type and composition
2 NC + 1 NO (slow-break, break before make)
Contact operation
Slow-break, break before make
Operating rate
10 cyc/mn for maximum durability
[Us] rated supply voltage
24 V - 15...10 %
Supply voltage type
AC/DC
Supply frequency
50/60 Hz
Minimum switching voltage
17 V
[Uimp] rated impulse withstand voltage
4 kV conforming to IEC 60947-5-1
Minimum switching current
10 mA at 20 °C
[Ui] rated insulation voltage
300 V conforming to UL 508, 300 V conforming to CSA C22.2 No 14, 250 V (pollution degree 3) conforming to IEC 60947-1
Signalling circuit voltage
24 V
[Ie] rated operational current
0.55 A at 24 V, DC-13, R300 conforming to IEC 60947-5-1, 0.75 A at 240 V, AC-15, C300 conforming to IEC 60947-5-1
[Ithe] conventional enclosed thermal current
4 A
Electrical shock protection class
Class I conforming to IEC 61140
Short-circuit protection
4 A cartridge fuse type gG (gl), 6 A type fast blow
Local signalling
1 LED (orange) for actuator withdrawn, 1 LED (green) for actuator inserted and locked
Maximum load current
<= 15 A
Signalling circuit type
AC/DC