Switch actuation
By 30° cam
Electrical connection
Male connector M12, 5 pins
Contacts insulation form
Zb
Positive opening minimum force
18 N
Minimum force for tripping
6 N
Maximum actuation speed
1 m/s
Repeat accuracy
0.1 mm on the tripping points with 1 million operating cycles
[Ie] rated operational current
3 A at 50 V, AC-15 conforming to IEC 60947-5-1 appendix A
0.27 A at 50 V, DC-13 conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
4 A
[Ui] rated insulation voltage
60 V (pollution degree 3) conforming to IEC 60947-1
Maximum resistance across terminals
25 MOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
0.8 kV conforming to IEC 60664
0.8 kV conforming to IEC 60947-1
Short-circuit protection
4 A cartridge fuse, type gG
Electrical durability
5000000 cycles, DC-13, 24 V, 10 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
15000000 cycles
Terminals description ISO n°1
(13-14)NO
(21-22)NC