Electrical connection
Male connector M12, 4 pins
Contacts insulation form
Za
Minimum force for tripping
8.5 N
Minimum actuation speed
0.01 m/min
Maximum actuation speed
0.5 m/s
[Ie] rated operational current
1.5 A at 240 V, AC-15 conforming to EN/IEC 60947-5-1 appendix A
0.1 A at 250 V, DC-13 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
3 A
[Ui] rated insulation voltage
250 V (pollution degree 3) conforming to IEC 60947-5-1
Maximum resistance across terminals
25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
2.5 kV conforming to IEC 60664
2.5 kV conforming to IEC 60947-1
Short-circuit protection
4 A cartridge fuse, type gG
Electrical durability
5000000 cycles, DC-13, 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Mechanical durability
10000000 cycles