Materials in contact with fluid
Stainless steel AISI 316L
Operating position
Any position
Protection type
Load short-circuit
reverse polarity
Electromagnetic compatibility
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 2 kV, electrostatic discharge immunity test conforming to IEC 61000-4-2 8 kV air, 4 kV contact, 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 1 kV 42 Ohm, immunity to magnetic fields conforming to IEC 61000-4-8 100 A/m 50 Hz, susceptibility to electromagnetic fields conforming to IEC 61000-4-3 10 V/m 80...3000 MHz, radiated RF fields conforming to IEC 61000-4-6 10 V 0.01...80 MHz
Response time on output
<= 2 ms 10...90 % of full scale
Measurement accuracy
+/- 0,5 % de la plage de mesure
Accuracy
0.1 % of the measuring range
Drift of the sensitivity
+/- 0,02 % of measuring range/°K
Drift of the zero point
+/- 0,02 % of measuring range/°K