ZCKL6

Limit switch body, Limit switches XC Standard, ZCKL, 1NC+1 NO, slow break, Cable gland include

arrow

Commercialized

green premium

Expand all

Datasheet

Range of product
Telemecanique Limit switches XC Standard
Series name
Standard format
Product or component type
Limit switch body
Device short name
ZCKL
Body type
Fixed
Product compatibility
XCKL
Associated head
ZCKD16
ZCKD239
ZCKD06
ZCKD029
ZCKD21
ZCKD08
ZCKD59
ZCKD91
ZCKD02
ZCKD10
ZCKD81
ZCKD17
ZCKD41
ZCKD219
ZCKD109
ZCKD23
ZCKD15
ZCKD05
Body material
Metal
Cable entry
1 tapped entry for Pg 13.5 cable gland (included)
Number of poles
2
Contacts type and composition
1 NC + 1 NO
Contact operation
Slow-break, make before break
Number of steps
1 1 position
Contacts material
Silver plated contacts
Local display
Without
Electrical connection
Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Positive opening
With
Minimum actuation speed
6 m/min
[Ie] rated operational current
3 A at 240 V, AC-15, A300 conforming to EN/IEC 60947-5-1 appendix A
0.27 A at 250 V, DC-13, Q300 conforming to EN/IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V (pollution degree 3) conforming to IEC 60947-1 for contact block
300 V conforming to CSA C22.2 No 14 for contact block
300 V conforming to UL 508 for contact block
Maximum resistance across terminals
0.25 mOhm conforming to IEC 60255-7 category 3
[Uimp] rated impulse withstand voltage
4 kV conforming to IEC 60664
4 kV conforming to IEC 60947-1
Short-circuit protection
6 A cartridge fuse, type gG
Electrical durability
5000000 cycles, DC-13 120 V, 1 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 24 V, 3 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13 48 V, 2 W, operating rate <60 cyc/mn, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
Width
52 mm
Height
72 mm
Depth
30 mm
Net weight
0.21 kg
Terminals description ISO n°1
(13-14)NO
(31-32)NC
(33-34)NO
IP degree of protection
IP66
IK degree of protection
IK05
Ambient air temperature for operation
-25…70 °C for standard environment
Ambient air temperature for storage
-40…70 °C
Environmental characteristic
Standard environment
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.3 cm
Package 1 Width
6.5 cm
Package 1 Length
8.0 cm
Package 1 Weight
226.0 g
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Mercury free
Yes
RoHS exemption information
Yes
Circularity Profile
No need of specific recycling operations
California proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Warranty