XCSRC11MM12

Preventa RFID safety switch, Telemecanique Safety switches XCS, contactless Standalone model EDM+Manual Start Unique pairing

arrow

COMMERCIALISED

Alle erweitern

Datenblatt

Commercial Reference
XCSRC11MM12
PIM CR type
Standard Commercial Reference
Product sub-type
Standard CR
Product typology
Referenced Sold Product
Short description
RFID SAFETY EDM MANUAL ST UNIQUE PAIRING
Medium description
Preventa RFID safety switch, Telemecanique Safety switches XCS, contactless Standalone model EDM+Manual Start Unique pairing
Website publication
1
Product manager
Yuan ZHANG
Base unit of measure
PCE
ERP-Print medium description
RFID SAFETY EDM MANUAL ST UNIQUE PAIRING
ETIM classification
ETIM 9 - EC002544 - Magnetic proximity switch
***TABLE***
Commercial status
08 - Commercialised
Warranty
-
Country of origin
FR (France)
Density of package
0 GRAM_PER_CUBIC_CENTIMETER
[BMEcat] Reach info
True
[BMEcat] RoHS indicator
True
Equipment category according to Annex I of EU RoHS 2011/65/EU
9i
1907/2006 - Reach regulation - Annex XVII status
Free of any substance listed in Annex XVII above threshold
California proposition
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
EU RoHS 2011/65/EU compliance status
Compliant with exemption(s)
1907/2006 - Reach regulation - EC number(s)
231-100-4;209-136-7;208-764-9;208-762-8
1907/2006 - Reach regulation - CAS number(s)
7439-92-1;556-67-2;541-02-6;540-97-6
1907/2006 - Reach regulation - SCIP ID
Ae2c9248-7cf2-40c5-9c81-79ca513bed7d
1907/2006 - Reach regulation - SVHC content(s)
Lead;Octamethylcyclotetrasiloxane (D4);Decamethylcyclopentasiloxane (D5);Dodecamethylcyclohexasiloxane (D6)
1907/2006 - Reach regulation - Specific safe conditions of use
None;None;None;None
1907/2006 - Reach regulation - Candidate list version
June 2025
2011/65/EU - RoHS - Exemptions according to Annex III
6(c);7(a);7(c)-I
GTIN
3389119634861
EAN13
3389119634861
Dangerous goods code
Not Applicable
Package 1 GTIN
3389119634861
Package 1 width
5 CENTIMETER
HS6 customs code (global)
853650
Package 1 height
1 CENTIMETER
Package 1 length
10 CENTIMETER
Package 1 weight
0.103 KILOGRAM
Volume of package 1
50 CUBIC_CENTIMETER
Indivisible sale quantity
1
Number of units in package 1
1
Unit type of package 1
PCE
Package 1 bare product quantity
1

Alle erweitern

Technische Zeichnungen

Dimensions

epds

Connections

M12 Connector, 8-pin

epds
  • (1) + 24 VDC
  • (2) OSSD2
  • (3) 0 VDC
  • (4) OSSD1
  • (5) EDM_ST_1
  • (6) EDM_ST_2
  • (7) NC (Not connected)
  • (8) NC (Not connected)

Connections

Wiring Diagram

epds
  • (1) Power Supply
  • (2) Reader
  • (3) Transponder
  • (4) 1 A max.
  • (5) Restart
  • (6) Use of arc suppressors for KM1 and KM2 is recommended.
  • (7) Power circuit

Mounting and Clearance

Mounting and Clearance

Face to Face Mounting (Preferred Configuration)

epds
  • e min. > 2 mm. (e: recommended minimum mounting distance between transponder and reader)
  • d : Detection limit

Mounting and Clearance

Side by Side Mounting

epds
  • e: Recommended minimum mounting distance between transponder and reader.

Mounting and Clearance

Minimum Mounting Clearances between Safety Switches

epds

Detection Curves

Face to Face Mounting (Preferred Configuration)

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.

Detection Curves

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) Recommended minimum mounting distance between transponder and reader.

Detection Curves

Side by Side Mounting

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.

Detection Curves

epds
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.
  • Sar: Assured release distance
  • Sao: Assured operating distance
  • (1) X=0 for X<0
  • (2) X=0 for X>0
  • (3) Recommended minimum mounting distance between transponder and reader.

Alle erweitern

Dokumente & Downloads

Dokumentenname
Datum
Größe
Dokumentenname
Datum
Größe
Dokumentenname
Datum
Größe

Alle erweitern

Verwandte Produkte & Zubehör

Back to top

arrow